| FIRE ALARM AND DETECTION SYSTEM |
| |
|
|
|
| |
FIRE PANELS
Fire panels provides a solution to fire detection. It can start from 2,4,6,8,10 & could go up to 60 zones of selcting models and features. These units have been designed to offer high standards of performance, reliability and quality. Suitable for small & big offices, workplaces, small and high rise buildings. Lamp test feature. Complete with integral power supply and battery charger for sealed lead acid battery. NO/NC contacts for both fire and fault. Short circuit, isolote, fire in each zone. These panels are easy to install, easy to operate and easy to maitain. |
|
|
|
|
|
|
| |
 |
| |
|
|
|
| |
PROTOTYPE (SMOKE DETECTOR)
These detectors are designed for applications where for applicatiions were low-voltage class 2 wiring is used. They have a built-in 85dB alarm horn. Up to 12 units can be interconnected so that if one detetor alarms, all detedtors alarm. Perfect for applications such as apartment bildings, the units are self-resetting.
> Built-in relay output with 8 second dela for connection to lights, bells, horns, remote annunciator, or control anel
> Built-in 85 dBA electornic horn
> Visibole LED for operational status
> Built-in test btton
> Units are self-resetting
> Sealed against dir, insectes, and back pressure
> Screw terminals for easy wiring
> Twist-on mounting braket with tamper-resistant option
> Ceiling white color
|
|
|
|
|
|
|
| |
 |
| |
|
|
|
| |
IONIZATION DETECTOR (SMOKE DETECTOR)
The sensing part of the detector consists of two chambers - an open, outer chamber and a semisealed reference chamber within. Mounted in the reference chamber is a low activity radicactive foil of Americium 241 whch enables current to flow between the inner and outer chambers when the detector is powered up. As smoke enters the detector, it causes a reduction of the current flow in the outer chamber and hence an increase in voltage measured at the junction between te two chambers. The voltage increase is monitored by the electronic circuitry which triggers the detector into the alarm state at a preset threshold. An externally visible red LED lights u when the detedtor changes to alarm state. An integrating ionisation detector, suitable for use in areas where transient levels of smoke may be expected, is also available. |
|
|
|
|
|
|
| |
 |
| |
|
|
|
| |
HEAT DETECTOR (SMOKE DETECTOR)
Heat detectors are intended for use in 2-wire / 4 wire class A or B supervised zone circuits. The detectors are subject to panel compatibility limits and compliance with corresponding standards, local codes, and ordinances. These detectors are designed with precise CPU control and thermistor detection. It ensures the best quality of heat detection in all environments. |
|
|
|
|
|
|